Miniature circuit breaker interlocking mechanism

WNHS Universal Interlock Attachment
Circuit breaker universal interlock accessory (hereinafter referred to as universal interlock), consisting of two-stage (multi-stage) circuit breakers and universal interlock assemblies, is mainly used in home life, business clubs, hotels, shopping malls and other occasions where two main circuits cannot work simultaneously.
The universal interlock, as a separate accessory, is assembled in the middle of a two-stage (multi-stage) circuit breaker. When it is necessary to switch lines, simply disconnect the current power circuit breaker, manually operate the locking screw sliding slider to drag the slider to the current power supply, and then close the power supply that needs to be switched to ensure that the two lines do not conduct at the same time, and switch the power supply safely at any time, playing a role in protecting the normal operation of the power supply line and electrical equipment or other electromechanical equipment.
Scope application
Circuit breaker universal interlock accessory (hereinafter referred to as universal interlock), consisting of two-stage (multi-stage) circuit breakers and universal interlock assemblies, is mainly used in home life, business clubs, hotels, shopping malls and other occasions where two main circuits cannot work simultaneously.
The universal interlock, as a separate accessory, is assembled in the middle of a two-stage (multi-stage) circuit breaker. When it is necessary to switch lines, simply disconnect the current power circuit breaker, manually operate the locking screw sliding slider to drag the slider to the current power supply, and then close the power supply that needs to be switched to ensure that the two lines do not conduct at the same time, and switch the power supply safely at any time, playing a role in protecting the normal operation of the power supply line and electrical equipment or other electromechanical equipment.
Normal working conditions
1. The surrounding air humidity is -40 ℃~+85 ℃, and its average value within 24 hours does not exceed+35 ℃. 2. The altitude shall not exceed 2000m.
3. The relative humidity of the air at the installation site under atmospheric conditions shall not exceed 50% at a maximum temperature of+40 ℃; Higher relative humidity is allowed at lower temperatures, with the average lowest temperature of the wettest month not exceeding+25 ℃ and the average maximum relative humidity of that month not exceeding 90%. And taking into account the condensation that occurs on the surface of the product due to temperature changes.
4. Pollution level: Level 2.
5. Installation category: Category II
6. Installation method: TH35-7.5 type guide rail is used.
Product size and installation method


Yueqing Yijin Electronics Co., Ltd.