Surge Protection Device

YJ1 Integrated Surge Protector (800V)

Product IntroductionThis series of surge protectors is suitable for TT, IT, TN-S, N-C-S and other power supply systems with AC 50Hz, 380V and below, and can be used as equipotential connections at the interface of LPZ1, LP22 and LP23 zones. Its design basis complies with IEC61643-1, GB18802.1, The shell is designed to be installed on…

  • YJ1 Integrated Surge Protector (800V)
  • YJ1 Integrated Surge Protector (800V)
  • YJ1 Integrated Surge Protector (800V)

  • YJ1 Integrated Surge Protector (800V)
  • YJ1 Integrated Surge Protector (800V)
  • YJ1 Integrated Surge Protector (800V)

YJ1 Integrated Surge Protector (800V)
This series of surge protectors is suitable for TT, IT, TN-S, N-C-S and other power supply systems with AC 50Hz, 690V/800V and below, and can be used as equipotential connections at the interface of LPZ1, LP22 and LP23 zones. Its design basis complies with IEC61643-1, GB18802.1, The shell is designed to be installed on a 35mm electrical rail, and the product has a built-in failure disengagement device. When the surge protector fails due to overcurrent, overheating, or breakdown, the failure disengagement device can automatically disconnect it from the power grid
The visual alarm indicator window changes from green (normal) to re···

Product Introduction

This series of surge protectors is suitable for TT, IT, TN-S, N-C-S and other power supply systems with AC 50Hz, 690V/800V and below, and can be used as equipotential connections at the interface of LPZ1, LP22 and LP23 zones. Its design basis complies with IEC61643-1, GB18802.1, The shell is designed to be installed on a 35mm electrical rail, and the product has a built-in failure disengagement device. When the surge protector fails due to overcurrent, overheating, or breakdown, the failure disengagement device can automatically disconnect it from the power grid

The visual alarm indicator window changes from green (normal) to red (fault).

Product Features

1. The protector unit can be replaced without changing the base;

2. Can withstand up to 40kA (8/21us) lightning current surge;

3. Action response time less than 25 nanoseconds;

4. The color of the visual window indicates the working status of the protection, green (normal) and red (fault).

5. High energy surge protection

6. Remote signaling alarm interface

7. Failure detection indication

8. Standard modular installation

9. Reaction speed: nanosecond level

10. Built in instantaneous overcurrent circuit breaker device

11. The maximum discharge current of a single module is 80kA (8/21uS)

12. Built in overheat circuit breaker device

Installation wiring diagram

YJ1 Integrated Surge Protector (800V)

Normal working conditions

1. The ambient air temperature ranges from -40 ℃ to+70 ℃, with an average value not exceeding+35 ℃ within 24 hours.

2. The altitude shall not exceed 2000m.

3. The relative humidity of the air at the installation site under atmospheric conditions shall not exceed 50% at a maximum temperature of+40 ℃; Higher relative humidity is allowed at lower temperatures, with the average lowest temperature of the wettest month not exceeding+25 ℃ and the average maximum relative humidity of that month not exceeding 90%. And taking into account the condensation that occurs on the surface of the product due to temperature changes.

4. Pollution level: Level 2.

5. Installation category: Category II

6. Installation method: Adopting international standard guide rails.

Main parameters and technical performance

model YJ1-C40
specifications 1P/2P/3P/4P
SPD category Pressure limiting type
Experimental category Class II experiment
Rated voltage Un 220V AC 50Hz
Maximum continuous operating voltage Uc (L-N) 690V/800V AC 50Hz
Nominal discharge current Ln (L-N) (8/20 μ s) 10kA20kA30kA
Maximum discharge current 1max (L-N) (8/20 μ s) 20kA 40kA 60kA
Voltage protection level Up (L-N) (8/20 μ s) 2.2kV
Voltage protection level Up (N-PE) (8/20 μ s) 2.2kV
Recommended series receiving current protection device 32A/10kA
Response time tA (L-N) ≤25ns
Failure indication Green: Normal Red: Failure
Installation of wire cross-sectional area 4-25mm²
Installation method 35mm standard guide rail
work environment -40——70℃
Housing material Plastic meets UL94 V-0 standards
protection grade IP20
Remote signaling alarm Normally open and normally closed contact terminals (optional)
Remote signaling interface wiring capability Maximum 1.5mm ²

Application and installation location

The YJ1 series module is used for equipotential connection during lightning strikes and is installed at the junction of LPZOB zone, LPZ1 zone, and LPZ2 zone. It is usually installed in floor distribution boxes, computer centers, telecommunications rooms, elevator control rooms, frequency conversion equipment control rooms, hospital operating rooms, monitoring rooms, and distribution boxes in places where electronic medical equipment is installed. SPD should be installed in residential distribution boxes for dispersed small villas.

Product design and ordering instructions: Users should clearly indicate the product model and quantity when designing and ordering products.

Product size parameters

YJ1 Integrated Surge Protector (800V)

When placing an order, it is necessary to specify the product model and quantity, for example: surge protector YJ1-C40 800V AC 80 units; Surge protector YJ1-C40 690V AC 100 units;

If there are special requirements, they should be noted separately.

For electrical maintenance and installation, it is necessary to ensure that the operator holds the qualification for electrical work and takes necessary power-off and insulation protection measures.